The following bugs were fixed in CLAMPEX V6.0.1
===============================================

*  The time corresponding to peaks is now correct for multichannel
   acquisitions.

*  The peak detection file now correctly contains the time in ms since the
   start of the episode when peaks occurred.

*  The Directory and Filename fields in the SavePeaks form are now read only
   and always equivalent to the SaveData path. i.e. Peak detection ATF files
   are now always saved in the Data directory with the same base name as the
   data file but with a .PKD extension.

*  Help is now available from within the SavePeaks form.

*  The next file number chosen for data file saving now skips over higher
   numbered .DAT and .PKD files in the data directory.

*  If a "record" is done with PeakDetection enabled, the peak detection ATF
   file is automatically written to disk with the same name as the data file
   except with the .PKD extension.

*  The Digital OUTs in the waveform preview screen have been relabeled
   according to the currently installed hardware type. So for the Digidata
   1200 they are shown as 0, 1, 2, 3 while for the TL-1 they are shown as
   C4, C5, C6, C7. Previously they were shown as 1, 2, 3, 4 unconditionally.

*  If a "record" is stopped during the first episode a data file is not
   created. Only complete episodes are ever saved in data files.

*  Changes to parameters made by "Hot Keys" are now tracked, the user being
   prompted to save modified parameters before exiting or loading a new
   parameter file.

*  If an invalid file type is used as a DAC file, the user is notified.

*  Use of DAC files now does not interfere with saving of parameter files.

*  Record acquisitions terminated before completion and not saved are no
   longer logged.

*  If a record acquisition with peak detection enabled is aborted, the peak
   is not saved, but when SavePeaks is selected the file will be saved to the
   file name that the aborted file would have had. (SaveData similarly)

*  The "Type" fields in Parameters/Waveform now accept non-ambiguous
   abbreviations of allowable entries.

*  The status field reporting amount of free space now copes with large
   (>2 GB) disk drives.

*  Improved diagnosis and speed testing of TL-1-40 digitizers.

*  Peak detect files are automatically saved if "Save" is selected after
   aborting a trial.

*  Limit of +/- 100 imposed on hot key adjustment of display gain.

*  Interrupting a trial with interepisode writing enabled, "Save" no
   longer causes screen corruption.

*  The calculation of a negative resistance value now no longer pauses the
   Seal-test acquisition.

*  The list of allowable entries for the number of Seal-test "Pulses per 
   resistance update" has been expanded to include "20" & "50".

*  The Seal-test resistance average is now a sliding average. The value of
   the sliding average is updated every 0.5 seconds.

*  Negative resistance values resulting from noisy seal-tests are no longer
   included in the sliding average.

*  Allowable values for Seal-test pulse magnitude have been expanded to 6
   values per decade. (1, 1.5, 2, 3, 5, 7, 10, 15, ...)

*  Browse status bar formatting has been improved so that large numbers do
   not get truncated by the edge of the screen.

*  First holding points now set correctly for DACFile acquisitions with
   holding "Use-last-epoch" enabled.

*  Digidata 1200 programmable gains now work for arbitrary channel sampling
   sequences.

*  Seal-test now puts out a SCOPE TRIGGER pulse at the start of each test
   pulse.

*  The sign of the seal-test pulse is now shown in the Seal-test sidebar.

*  The <Up-Arrow> and <Down_Arrow> hotkeys in Seal-test now allow the user to
   take the pulse through zero into the opposite polarity.

*  The list of supported telegraph instruments has been expanded to include
   the DAGAN CA-1 and Warner OC-725.

*  Axopatch gain telegraphs now return correct values in Current Clamp mode.

*  Interruption of trials with telegraphs enabled no longer causes a
   "Timeout waiting for ADC conversion." error message when using the
   DIGIDATA-1200 digitizer.

*  Fast loading sequences no longer skip sequence numbers when the sequences
   contain a mixture of "View" and "Record" acquisitions.

*  The HotChannel window number is retained between FastLoading trials, and
   saved in the CLAMPEX.INI file.

*  The Parameters/Train form validation now interacts correctly with the 
   UserList settings.

*  If a Trial recording is interrupted and discarded, the Manual Information
   form is not shown.

*  Minor bugs were fixed in the getinfo screen.



The following bugs were fixed in CLAMPEX V6.0.2
===============================================

*  The list of supported telegraph instruments has been expanded 
   to include an additional gain entry for the DAGAN CA-1: Im Gain = 10.

*  A field for communications speed was added to the Configure/Hardware 
   form ("Serial port speed").  Options are "Fast" and "Slow", with 
   "Fast" being the default.  "Fast" is 9600 baud; "Slow" is 2400 baud. 
  
*  If the current data path becomes invalid (open floppy drive, or  
   remapped drive alias) the program diagnoses it gracefully.     
     
*  Conditioning trains now contain the correct number of pulses if  
   the post-train period is non-zero.    
    
*  Timings are now correct for P/N acquisitions with a non-zero  
   settling time.    
    
*  The File/GetInfo screen has had several minor formatting changes 
   made to it.    
     
*  Clarification of connections for DAGAN CA-1 instruments:  
   The user should connect "Im Proc" to the gain telegraph input.  
   Do NOT connect "Im Gain" to this input.   
   
*  Large sampling intervals can now be used in split clock  
   acquisitions without getting the UNEXPECTED ERROR, ID=13' message.   
    
*  Clampex now supports reading of ABF files written by AxoData (on  
   the Macintosh).     
     
*  A field for setting an I/O delay length field ("Timing Loop  
   Count") was added to the Configure/Hardware form to solve timing  
   problems on EISA bus computers by adding additional wait states.  
   Its default value is unity.   
     
*  The split clock transition point for large episodes can now be as  
   short as one sample.  Previously, very small transition point values 
   had caused the program to crash.   
    
*  The FastLoading of chained parameter files now works correctly  
   when the time of day passes midnight.     
    
*  Episodes up to 16384 samples long may now be used successfully in  
   combination with DAC files.    


The following bugs were fixed in CLAMPEX V6.0.3
===============================================

*  SealTest no longer crashes if the loaded protocol has less than 512 
   samples. 

*  Loading parameter files written by old versions of CLAMPEX with no
   epochs defined no longer causes a crash.

*  The time stamp applied when logging successful acquisitions is now 
   correct.
   
*  Time between episode (or run) starts is no longer validated if 
   space-bar or external triggering is enabled. 
   
*  When leak-subtracted data goes out of the range of the ADC converter
   it is clipped at the limit of the ADC converter. i.e. Saved data
   is now clipped at the same level as is shown on the screen during 
   acquisition.

*  Epoch limited peak-detection in multi-channel acquisitions now 
   correctly limits the search region to the epoch selected.
   
*  The "Start" and "End" positions for peak detection is now in 
   "per-channel" samples rather than "multiplexed-samples".
   
*  The system time-of-day clock no longer falls behind when doing
   rapid repetitions of short trials.

*  The validation of scale and offsets in the TestSeal form has been relaxed
   to allow smaller numbers.

*  The File/OpenData form now allows the use of the *.ABF template.

The following bugs were fixed in CLAMPEX V6.0.4
===============================================

*  Scaling factors corrected for Warner telegraphs.

*  Support for Digidata 1200C added.

*  Additional I/O wait states added for compatibility with faster processors.

*  DAC Scaling factors can now be specified with 3 digits after the decimal
   point.